Modify Bits Outgoing Panel - Alcatel-Lucent 1850 User Provisioning Manual

Transport service switch
Table of Contents

Advertisement

Menu bar
............................................................................................................................................................................................................................................................
Figure 3-69 Modify BITS outgoing panel
The Modify BITS OUT panel contains the following fields:
Access Identifier - Specifies the Access Identifier of the selected BITS.
DS 1 Format - Specifies the signal time for the timing input port. The values are
2MHZ, 2MBIT-NOSSM, and 2MBIT-SSM. If the user selects 2MBIT-SSM, the SA
bit location is displayed. The default value is the previous existing value. If the
existing value is empty, the default factory value is 2MHZ for SDH mode.
SA Bit Location - Specifies the SA bit location used to carry the SSM information.
The values are SA4, SA5, SA6, SA7, and SA8. The default menu value is the previous
existing value. If the existing value is empty. The default existing value is SA4.
Transmitted ESF - Specifies if the output signal is the DUS message or is the actual
SSM value. The values are DUS and ACT. The default value is the previous existing
value. If the existing value is empty. The default existing value is DUS.
The Default hyperlink allows to recover the previously existing value or the factory
default (Actual).
ENABLE OUTPUT - Specifies the output mode to which the facility is set. The
values are Y and N. The default value is N.
AIS Mode - Specifies which signal is inserted for the timing output port if the output
signal is squelched. The values are AISMODE and QLMODE. The default values is
the previous value. If the existing value is empty, the default factory value is
QLMODE.
Outgoing Signal Quality - Specifies the quality value level for the out-going signal at
the timing output port. The values are PRC, SSUL, SSUT, SEC, and DUS.
SSM Supported - Specifies whether the timing input port supports SSM or not. The
values are Y and N.
The panel has the Save hyperlink that is used to send the related command to the Network
Element. Automatically is loaded the Modify BITS OUT page to show update data.
Synchronization
This menu option contains the following four sub-menus:
Search - To retrieve and edit synchronization resources related to a given shelf
............................................................................................................................................................................................................................................................
3 - 74
Synchronization menu
8DG08763KAAA
Issue 1 February 2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tss-320Tss-160

Table of Contents