Procedures
............................................................................................................................................................................................................................................................
Table 5-14 ASAP CREATE Parameters
Parameter
ASAP Type
Default
User Label
........................................................................................................................................................................................................................
4
Click Cancel to revoke all the settings and return to the previous page.
........................................................................................................................................................................................................................
Click Save & Exit to store all the settings and return to the previous page.
5
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
5 - 78
S
F
T E P S
Description
Lists all the available ASAP type, but without
the prefix ASAP. The allowable values are:
ALL = all alarms
•
EQPT = equipment alarms
•
COM = common parts alarms
•
BITS = synchronism alarms
•
SECU = administration security alarms
•
OCn = OCn (where n = 3, 12, 48 or 192)
•
alarms
STSn = STSn (where n = 1, 3c, 12c, 48c or
•
192c) alarms
GBE = Gigabit Ethernet alarms
•
10GBE = 10 Gigabit Ethernet alarms
•
10GFC = 10 Generic Flow Control alarms
•
VCG = Virtual Concatenation Group
•
alarms
ODU2 = ODU2 port alarms
•
OTU2 = OTU2 port alarms
•
OCHPORT = Optical Channel port alarms
•
OTSPORT = Optical Transmission Section
•
port alarms
OSCPORT = Optical Supervisory Channel
•
port alarms
Allows to indicate whether the ASAP will
become the default ASAP for that ASAP type
or not. The allowable value are: "Y" or "N".
Digit a mnemonic string of the ASAP.
Create ASAP
8DG08136EAAA
Issue 3 July 2009