– OOS-MA Out of Service, Management - The module is out of service due to
– OOS-AUMA Out of Service, Autonomous and Management - The module is out
Automatic In Service Mode - To change the Automatic in service mode to which the
unit is set. The choices are:
– NOWAIT - A condition notifies the module is unplugged.
– AINS - No condition is sent due to module unplugged.
Auto-Provisioning - Specifies the Auto provisioning parameter is used to manage the
Autoprovisioning functionality in case of global (Shelf/NE level) restart: its main
purpose is to prevent the autoprovisioning of a Card (after a restart) in a slot position
in which it has been logically deleted. It cannot be provisioned, it is managed only by
the NE but can be retrieved. The choices are:
– ON - Autoprovisioning Allowed in that slot position.
– OFF - Autoprovisioning Not-Allowed in that slot position.
Command Mode - To change the status of the unit. The values are:
– NORM (normal)
– FRCD (forced)
Alarm Profile - Specifies the label of the ASAP that is used for the unit. Click Select
hyperlink to select a different profile.
The Restart panel displays the following parameters:
Access Identifier - Specifies the Access Identifier of the equipment.
Phase - Specifies to check the status of the unit. The default value is COLD.
Command Mode - To change the status of the unit. The values are:
– NORM (normal)
– FRCD (forced)
The panel has the following hyperlinks:
Save - To apply the settings and restart with new selection.
Remove - Causes the specified facility client/line to be placed in an out-of-service
(OOS-MA or OOS-AUMA) state for maintenance purposes.
The Alarm panel contains the View hyperlink that allows to show all the actual alarm.
The VCG resources available selection panel allows to show available VCG resources.
The table contains the following details relevant to the unit:
Module - Lists all the available module of the unit.
Resource - Specifies the access identifier of the module (type and position). It is also
shown in the tree. Click Resource link, the Rack x > Shelf x > Board xx > Module
xx tab is displayed. See
PST - Specifies the primary state of the module.
............................................................................................................................................................................................................................................................