Alcatel-Lucent 1850 TSS-320 User Provisioning Manual page 206

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
The Rack x > Shelf x > Board xx tab page presents two panels and a table. The Rack x >
Shelf x > Board xx panel contains the following parameters:
Access Identifier - Specifies the Equipment Access Identifier, identifies the
equipment entity access identifier
Current Provisioned Type - Specifies the Provisioned module type. It is also shown
in the tree. The values are:
– TBUS320 Termination Bus (Alcatel-Lucent 1850 TSS-320/160)
– EC320 Equipment Controller (Alcatel-Lucent 1850 TSS-320/160)
– MT320 Matrix and Timing (Alcatel-Lucent 1850 TSS-320/160)
– POW320 Power (Alcatel-Lucent 1850 TSS-320/160)
– FAN320 FAN Unit Tray (Alcatel-Lucent 1850 TSS-320/160)
– 1P10GSO 10G Synchronous Optical
– 4P2G5SO 4x2.5G Synchronous Optical
– 8PSO 8 x Synchronous Optical
– 10XANY 10GB 10 x GBE/Sonet
– PP20G 4 port 20G L2 Switch
– PIMMS (PIM MUltiservice 10G)
– PIM1GE (PIM 10x1GE Optical)
– PIM10GE (PIM 1x10GE Optical)
– LDRXA (Receiver Amp16 dBm + OSC)
– LDRXB (Receiver Amp20 dBm + OSC)
– LDTXA (Transmitter Amp20 dBm + OSC)
– LDTXB (Transmitter OSC)
– OPS (Optical Protection Switch)
– WR4 (Wavelenght Router - four optical lines)
– WR8 (Wavelenght Router - eight optical lines)
– 11GBAR (single port 11G bidirectional anyrate optical translator)
– 11GUAR (single port 11G unidirectional anyrate optical translator (drop))
– OMD44 (optical channel multiplexor/demultiplexor - 44 channels)
Actual Type - Specifies the physically equipped module type (see Current
Provisioned Type).
Primary/secondary state - Specifies the primary and secondary service state.
Primary State - To change the primary state to which the unit is set. The choices are:
– IS: In Service - The module is providing service.
– OOS-AU Out of Service, Autonomous - The module is out of service due to an
............................................................................................................................................................................................................................................................
4 - 28