configured on an adjacent pair of cards, with the Protected/West port in the lower
numbered slot and Protecting/East port in the next higher numbered slot. For optical
modules that support multiple ports, the port numbers specified must be same for both the
working and the protection entities.
Selecting the Protection -> APS (Automatic Protection System) menu path, the following
page will appear:
Figure 3-55 Protection Page -> APS
The APS page displays the Filter by panel that contains the following parameter:
– Signal - The values are:
The Search is used to start the search activity.
The Create link is used to configure a new APS. See
UPSR
This procedure allows the operator to create an FFP that associates a Protecting or East
OC-192 facility with a Protected or West facility. When multiple facilities are supported
by module, grouping facility number on EAST and the facility number on the WEST
module must be same. i.e., port 1 OCn facility on EAST must be paired with port 1 WEST.
Similarly port 2 on EAST must be paired with port 2 on WEST facility to form a BLSR2
group.
The OC-n ports must be configured on adjacent pair of cards with the Protected/West port
in the lower-numbered slot and Protecting/East port in the next higher slot. For optical
modules that support multiple ports, the port numbers specified must be same on both the
working and the protection entities.
............................................................................................................................................................................................................................................................
8DG08136EAAA
Issue 3 July 2009
•
ALL
•
OC3
•
OC12
•
OC48
•
OC192
"Create APS" (p. 5-91)