Alcatel-Lucent 1850 TSS-320 User Provisioning Manual page 212

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
– ANY-OC12 Generic MSA SFP module (STM4 case)
– ANY-OC48 Generic MSA SFP module (STM16 case)
– ANY-OC192 Generic MSA XFP module (STM64 case)
– ANY-DATAS Generic MSA SFP module (Ethernet GBE case)
– ANY-DATAX Generic MSA XFP module (Ethernet 10GBE case)
Actual Type - Specifies the Physically equipped module type (see Current
Provisioned Type).
Primary/secondary state - Specifies the primary and secondary service state.
Primary State - To change the primary state to which the unit is set. The choices are:
– IS: In Service - The module is providing service
– OOS-AU Out of Service, Autonomous - The module is out of service due to an
– OOS-MA Out of Service, Management - The module is out of service due to
– OOS-AUMA Out of Service, Autonomous and Management - The module is out
Automatic In Service Mode - To change the Automatic in service mode to which the
unit is set. The choices are:
– NOWAIT - A condition notifies the module is unplugged
– AINS - No condition is sent due to module unplugged
Auto-Provisioning - Specifies the Auto provisioning parameter is used to manage the
Autoprovisioning functionality in case of global (Shelf/NE level) restart: its main
purpose is to prevent the autoprovisioning of a Card (after a restart) in a slot position
in which it has been logically deleted. It cannot be provisioned, it is managed only by
the NE but can be retrieved. The choices are:
– ON - Autoprovisioning Allowed in that slot position
– OFF - Autoprovisioning Not-Allowed in that slot position
Command Mode - To change the status of the unit. The values are:
– NORM (Normal)
– FRCD (Forced)
Alarm Profile - Specifies the label of the ASAP that is in used for the unit. Click
Select hyperlink to select a different profile.
The Alarm panel contains the View hyperlink that allows to show all the actual alarm.
............................................................................................................................................................................................................................................................
4 - 34
autonomous event.
management action.
of service both due to an autonomous event and management action.
Access a module
8DG08136EAAA
Issue 3 July 2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1850 tss-160

Table of Contents