Parameter
Cross Connect Type1
Cross Connect Type2
Circuit Identifier
Preferred
Switch on UNEQ-P
Revert
............................................................................................................................................................................................................................................................
8DG08136EAAA
Issue 3 July 2009
Description
It indicates the type of cross-connection. The possible
values are:
One-way(1WAY): One-Way, identifies an
unidirectional connection between the selected
FROM and TO facility ports.
One-Way Path Protected Ring(1WAYPR):
Identifies a cross connect in which a protected path is
dropped from a UPSR Ring. No path is added.
One-Way Pass Through Ring(1WAYTHRU)
Two-way(2WAY): Two-Way, identifies an atomic bi-
directional connection between the selected FROM
and TO facility ports.
Two-Way Path Protected Ring(2WAYPR): Two-
Way Path Ring. Delete a two-way path ring cross
connection between the FROM and TO ports that are
embedded within OC-n that are defined to be in UPSR
relationship.
Two-Way Drop-and-Continue Ring-to-Ring
(2WAYDCRR): Identifies a double bi-directional
Drop and Continue cross-connection between the
selected FROM on one ring and the selected TO on
the second ring. Used for dual node ring interconnect.
Bidirectional ring pass-through(THRU)
It indicates the second ring cross-connection type (for dual
ring interconnect only). The possible values are:
Two-way(2WAY)
Two-Way Path Protected Ring(2WAYPR)
It indicates the FROM-TO or To-FROM circuit ID
previously assigned to cross-connection. The possible
values are: < 1-45 VALID CKTID CHARACTERS >.
It indicates the preferred direction for a cross-connect
selector function.
It indicates whether or not to switch when an UNEQ-P
condition occurs. This parameter is only applicable to
non-pass-through cross-connections in UPSR. The
possible values are: N (do not switch on UNEQ-P) or Y
(switch on UNEQ-P).
It indicates whether or not to make revert to working once
the working comes into service and the traffic is on
protect. This parameter is only applicable to non-pass-
through cross-connections in UPSR. The possible values
are: N (do not revert to working/preferred) or Y (revert to
working/preferred).