Synchronization menu

Purpose
This menu allows the operator to manage the ports dedicated to BITS (Building Integrated
Timing Supply) facilities for clock distribution purposes. A BITS output reference is a
DS1 signal. The menu options are:
BITS - Allows to modify the characteristics (BITS-0 as Primary and BITS-1 as
Secondary) and the outgoing port of reference clock.
Synchronization - Allows to modify the parameters of the synchronization system.
BITS
This menu option contains three sub-menu options:
Modify BITS-0 - Allows to edit bit 0 related to a given shelf.
Modify BITS-1 - Allows to search and edit bit 1 related to a given shelf.
Modify BITS-OUT - Allows to search and edit bit out related to a given shelf.
Modify BITS-0 and BITS-1
Select Synchronization -> Bits -> Modify BITS-0 or Synchronization -> Bits ->
Modify BITS-1 as shown in
Figure 3-58 Modify BITS-0 or BITS-1 panel
The "Modify BITS-0" and "Modify BITS-1" are the same panel with the two different
Access Identifier values. The panel contains the following fields:
Access identifier: - Specifies the access identifier for the selected BITS
............................................................................................................................................................................................................................................................
3 - 66