Tree area
............................................................................................................................................................................................................................................................
Figure 4-39 PM Init Register tab for DWDM module (e.g. XFP)
The PM Init Register functional tab has the Initialize Register panel which allows to
set the parameters for the PM collection. It contains:
The panel has the following hyperlinks:
– Cancel: By clicking this hyperlink the user leave the page.
– Save: By clicking this hyperlink the user saves the settings.
3. PM Mode functional tab
............................................................................................................................................................................................................................................................
8DG08136EAAA
Issue 3 July 2009
Access Identifier: It identifies the entity access identifier in the <OTPORT>-
<rack>-<shelf>-<slot>-<side> format. It is also shown in the tree.
Monitored Parameter Type: It identifies the parameter whose PM data register is
being initialized. Only all near-end and/or far-end parameters of the current 15
minutes or 1 day register can be initialized. The Default value is ALL.
Monitor Value: It specifies the value to be set in the register specified by Location
and Time Period. Only the value 0 is supported. The Default value is 0.
Location: It specifies the PM registers location to be initialized. The Default value
is NEND (near end).
Direction: It specifies the direction of the signal being monitored (receive or
transmit). The allowable values are: RCV (receive) or TRMT (transmit) or ALL
(both). The Default value is RCV.
Time Period: It specifies whether the 15-minute or 1-day (24 hour) PM collection
register is to be initialized. The allowable values are: 15-MIN (receive) or 1-DAY
(transmit). The Default value is 15-MIN.