Alcatel-Lucent 1850 TSS-320 User Provisioning Manual page 298

Transport service switch
Table of Contents

Advertisement

Procedures
............................................................................................................................................................................................................................................................
Description: The entry box allows to digit a connection description assigned by user
in the Control Plane for the Network CALL.
Replace (using make-before-break technique): The entry box allows to digit the
present connection replacement using make-before-break technique.
Direction: The combo-box allows to select the CALL connection direction
(unidirectional/bidirectional). Possible values:
– UNIDIR unidirectional
– BIDIR bidirectional
Call Type: The combo-box allows to select the significance for the Call identifier
parameter. Possible values:
– OPERATOR Call Identifier has a format for local significance.
– GLOBAL Call Identifier has a format for global significance.
Source Port ID: The entry box allows to digit, in the <rate>-<rack>-<shelf>-<slot>
format, the Service termination Port Access Identifier. It is located on the originating
node of the connection. Port AID can be an OC-n facility or a VCG termination type.
Destination Port ID: The entry box allows to digit, in the <rate>-<rack>-<shelf>-
<slot> format, the Service termination Port Access Identifier. It is located on the
destination node of the connection. Port AID can be an OC-n facility or a VCG
termination type.
Source Label: The entry box allows to digit a generalized Label value to be used at
connection source on ingress node port. Label format is defined only for SONET layer
(TDM label type) <five dash separated numeric string> S#-U#- K#-L#-M# format.
Possible values:
– S#={0 - 65535} (Index of STS-3/AUG-1 within a STS-3xN /STM-N multiplexed
– U# = {0 - 15} (Index of STS-1-SPE/VC-3 within a STS-3/AUG-1 signal)
– K# = {0 - 15} (Index of TUG-3 within a VC-4 signal)
– L# = {0 - 15} (Index of VT-Group/TUG-2 within a STS-1-SPE/TUG-3 or VC-3
– M# = {0 - 15} (Index of VT1.5-SPE/VC11 or VT2-SPE/VC12 or VT3-SPE within
Destination Label: The entry box allows to digit a generalized Label value to be used
at connection destination on egress node port. Label format is defined only for SONET
layer (TDM label type) <five dash separated numeric string> S#-U#- K#-L#-M#
format. Possible values:
– S#={0 - 65535} (Index of STS-3/AUG-1 within a STS-3xN /STM-N multiplexed
– U# = {0 - 15} (Index of STS-1-SPE/VC-3 within a STS-3/AUG-1 signal)
– K# = {0 - 15} (Index of TUG-3 within a VC-4 signal)
............................................................................................................................................................................................................................................................
5 - 38
signal)
signal)
a VTGroup/TUG-2 signal)
signal)
Control Plane - Signaling: Create Network Call
8DG08136EAAA
Issue 3 July 2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1850 tss-160