Alcatel-Lucent 1850 TSS-320 User Provisioning Manual page 218

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
PM registers, or the current and/or up to seven (7) 1-day historical PM registers or both
15-minute and 1-day PM registers can be retrieved.The page shows the following
parameters:
– Monitor Level: The combo-box allows to set the discrimination level of PM
– Down: Only PM data for the specified MONTYPE that is less-than or equal-to ( <
– Down Or Not Complete: Only PM data for the specified MONTYPE that is < the
– Up: Only PM data for the specified MONTYPE that is greater-than or equal-to ( >
– Up Or Not Complete: Only PM data for the specified MONTYPE that is > the
Clicking on the Default hyperlink it is possible to set the default value UP.
– Near End
– Far End
– All
Clicking on the Default hyperlink it is possible to set the default value ALL.
– Code Violations - Section (CVS)
– Errored Seconds - Section (ESS)
– Severely Errored Seconds - Section (SESS )
– Severely Errored Frame Seconds - Section (SEFSS)
– Unavailable Seconds - Section (UASS)
– Code Violations - Line (CVL)
– Errored Seconds - Line (ESL)
– Severely Errored Seconds - Line (SESL)
– Unavailable Seconds - line (UASL)
– Failure Counts - Line (FCL)
– Protection Switching Counts - Line (PSCL)
– Protection Switching Duration - Line (PSDL)
– All monitored types- (ALL)
............................................................................................................................................................................................................................................................
4 - 40
Access Identifier: The entry box specifies the identifier of the unit resource. It is
also shown in the tree.
parameter values to be reported for the specified Monitored Parameter Type. The
allowable choices are:
) the value of < LEVEL> is reported.
value of <LEVEL> or that does not have a VLDTY flag of CMPL.
) the value of < LEVEL> is reported.
value of <LEVEL> or that does not have a VLDTY flag of CMPL.
Location: The combo-box allows to specify whether PM registers for near-end
and/or far-end PM monitoring are to be reported. The allowable choices are:
Monitored Parameter Type: The combo-box allows to specifies the type of
monitored parameter whose PM data registers are being retrieved. The allowable
choices are:
Access a resource
8DG08136EAAA
Issue 3 July 2009