Alcatel-Lucent 1850 TSS-320 User Provisioning Manual page 252

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
Figure 4-40 PM Mode tab for DWDM module (e.g. XFP)
The PM Mode functional tab has the Set Performance Monitoring Mode and Retrieve
Performance Monitoring Mode panels which allow to set the parameters for the PM
collection. They contain the following parameters:
The panels have the following hyperlinks:
– Cancel: By clicking this hyperlink the user leave the page.
– Save: By clicking this hyperlink the user saves the settings.
– Retrieve: By clicking this hyperlink the user starts the PM data mode.
4. PM Baseline functional tab
............................................................................................................................................................................................................................................................
4 - 74
Access Identifier: It identifies the entity access identifier in the <OTPORT>-
<rack>-<shelf>-<slot>-<side> format. It is also shown in the tree.
Location: It specifies the PM registers location to be initialized. The Default value
is NEND (near end).
Mode Type: It specifies the PM mode type to be enabled or disabled. The
allowable values are: All (PM for all applicable parameters is configured) or S
(PM for OTUk Section parameters is configured) or O (PM for Optical analog
parameters is configured). The Default value is O.
Direction: It specifies the direction of the signal being monitored (receive or
transmit). The allowable values are: RCV (receive) or TRMT (transmit) or ALL
(both). The Default value is RCV.
PM State: It specifies whether the PM data collection for the specified mode type
is enabled or disabled. The allowable values are: ON (PM for the specified
MODETYPE is enabled) or OFF (PM for the specified MODETYPE is disabled).
The Default value is ON.
Access a resource
8DG08136EAAA
Issue 3 July 2009

Hide quick links: