Procedures
............................................................................................................................................................................................................................................................
Parameter
Protected Access Identifier
Protecting Access Identifier
Revert Delay Time
Local Node Identifier
Node Description
........................................................................................................................................................................................................................
4
Click Save to save the settings and return to the previous page.
........................................................................................................................................................................................................................
Click Cancel to revoke all the settings and return to the previous page.
5
E
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
8DG08136EAAA
Issue 3 July 2009
O
S
F
T E P S
Description
It is the Access Identifier of the West/Working/Preferred
member of the FFP. The Select hyperlink allows to start
the selection process. After the selection procedure, the
chosen value will be reported.
It is the Access identifier of the East/Protection/Alternate
member of the FFP.
This parameter is only applicable to non-pass-through
cross-connections. By means of the combo-box, it is
possible to chose the time in a 0 to 15 seconds range, the
default value is 5 seconds.
This parameter identifies the node identifier of the BLSR
node. By means of the combo-box, it is possible to chose
the identifier number in a 0 to 15 range, the default value
is the previously existing value.
Describes the Node.
Create BLSR
5 - 9 5