2.3 Error/Status Code List

For information about the following FIP items described in "FIP to be referred"
column in the following table, refer to the manual of each Option unit.
FIP1.22 through 25: Option 550 Paper Feeder
FIP1.26 through 32: Option Duplex
FIP1.37 through 43: Option OCT
Chain Link Fault Items
001
300 Top Cover Open
001
301 Rear Cover Open
001
302 OCT Cover Open
001
306 Duplex Cover Open
001
398 FAN Motor Fail
Scope-FD send error
003
346
detected by
Controller(Parity error)
Scope-FD send error
003
347
detected by
Controller(Framing error)
Send error detected by
Controller Detect
003
348
incorrect command in
sending ENOSTR
Send error detected by
003
349
Controller Sending under
runESPIPE
Varieties of errors
003
350
detected by Controller
EIO
Parity error is caused in
003
354
receiving a status from
IOT
Overrun is caused in
003
356
receiving a status from
IOT
Initialization error
003
360
between IOT-ESS
PAGE-SYNC is caused
003
362
before the preparation of
video output is completed.
Conditions of detect/Methods of treatment
Detect Top Cover or Top Cover & Rear Cover OpenDefect of SWITCH
I/L ASSY, Confirmation of contact/wiring
Detect Rear Cover Open onlyDefect of INTERLOCK S/W REAR,
Confirmation of contact/wiring
Detect OCT Cover OpenDefect of SWITCH REAR COVER,
Confirmation of contact/wiring
Detect Duplex Cover OpenDefect of SWITCH DUPLEX, Confirmation
of contact/wiring
One of FAN MAIN or FAN SUB doesn' t rotate in specified revolutions.
Check Main Fan/Sub Fan and MCU and replace as needed
Communication fails is caused because ACK is not received by resend
in twice.Parity error is detected in HARDWARE of IOT side.
If the trouble is not recovered by powering OFF and ON, execute the
following.
- Check the connection of HVPS/MCU connect harness.
- If the trouble is still caused, replace HVPS/MCU PWB.
Framing error is caused because ACK is not received by resend in
twice.
If the trouble is not recovered by powering OFF and ON, execute the
following.
- Check the connection of HVPS/MCU connect harness.
- If the trouble is still caused, replace HVPS/MCU PWB.
Power OFF and ON
Power OFF and ON
Power OFF and ON
It is caused when receiving NAK which reporting the communication
fail.
Check the connection of HVPS/MCU connect harness.
If the trouble is still caused, replace HVPS/MCU PWB.
It is caused when receiving NAK which reporting the communication
fail.Check the connection of HVPS/MCU connect harness.
If the trouble is still caused, replace HVPS/MCU PWB.
Fail to initialize IOT (MCU).
Check the connection of HVPS/MCU connect harness.
Replace HVPS/MCU PWB.
PageSync becomes active before writing output data until buffer
becomes full when printing.
Replace the harness to connect ESS and IOT.
Replace ESS PWB.
1 - 7