Oki B6200 Maintenance Manual page 24

Hide thumbs Also See for B6200:
Table of Contents

Advertisement

Chain Link Fault Items
PAGE-SYNC finish error
003
363
in outputting video
003
364 DMA transfer error
Other errors from
003
367
Decompress
003
368 PCI Bus Error
003
370 Marker code detect error
IOT-ESS Communication
003
371
Fail 1
IOT-ESS Communication
003
372
Fail 2
003
600 Billing Fail 3
003
601 Billing Fail 4
003
602 Billing Fail 5
003
747 Print Instruction Fail
003
946 Tray 1 Not In Position
Conditions of detect/Methods of treatment
PageSync becomes inactive before the specified size is printed out
when printing.
Replace the harness to connect ESS and IOT.
Replace ESS PWB.
Compression/decompress is not finished though the specified data is
input when compressing or decompressing.
Insert and remove RAM on ESS PWB (if it exists)
Execute the DC355 DIAG test, and replace HDD if the trouble is not
recovered.
Replace ESS PWB.
Detect Line Sync incorrectly.
Connection of connecters between ESS PWB J32 and MCU PWB J14,
disconnection of Flat Cable, or loose connection.
Replace ESS PWB if no problem with Flat Cable.
Access of PCI causes trouble due to the defect of PCI bus.
When it is not recovered by powering OFF and On, replace ESS PWB.
The finish code is not found in the compressed data (FF02) when
depressing the data in specified size.
When it is not recovered by powering OFF and On, execute the
following.
In case of that the specific documents cause the trouble. The
possibility of software problem is high.
1. Changing print mode (normal/high quality/high resolution) may print
out.
2. Changing RAM size may print out.
A. Change RAM size to install
B. Change the used size of RAM (Change the setting of port, or
received buffer size)
In case of that the most of documents cause the trouble. The
possibility of hardware problem is high.
1. Change RAM
2. Execute the DC355 DIAG test, and replace HDD if the trouble is not
recovered.
3. Replace ESS PWB
No response from IOT PWB to ESS PWB sending.MCU PWB J14,
disconnection of Flat Cable, or loose connection.
Replace ESS PWB if no problem with Flat Cable.
When it is not recovered yet, replace MCU PWB.
ESS PWB detects DLL send error.
MCU PWB J14, disconnection of Flat Cable, or loose connection.
Replace ESS PWB if no problem with Flat Cable.
When it is not recovered yet, replace MCU PWB.
Auto recovery of Billing Master Counter.
Already registered to History (Hide Fail)
Auto recovery of Billing Backup Counter 1.
Already registered to History (Hide Fail)
Auto recovery of Billing Backup Counter 2.
Already registered to History (Hide Fail)
The combinations of printing parameter is not correct such as sets
[Tray paper size] to[Auto] of operational panel, sets [Select paper tray]
to[Auto] of printer driver, and indicates the printing in indeterminate
size.Check printing indication.
Tray 1 is not set.
Defect of GUIDE TRAY L ASSY
Disconnection of wires from GUIDE TRAY L ASSY J180 to MCU PWB
J18 or loose connection.
Defect of MCU PWB
1 - 8
Chapter 1 Troubleshooting
Ref FIP
-
-
-
-
-
-
-
-
-
-
-
FIP1.13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B6300

Table of Contents