Removal
1)
Remove the COVER REAR 500 (PL10.2.21). (RRP10.9)
2)
Remove the COVER REAR (PL1.1.3). (RRP1.1)
3)
Remove the COVER LEFT (PL1.1.6). (RRP1.3)
4)
Remove the COVER RIGHT (PL1.1.4). (RRP1.2)
5)
Remove the COVER EXIT 500 (PL10.1.1). (RRP10.1)
6)
Remove the CHUTE UP EXIT (PL10.1.4). (RRP10.3)
7)
Remove the ACTUATOR FULL STACK from the CHUTE UP EXIT by moving it in the direction of
the arrow.
Replacement
1)
Install the ACTUATOR FULL STACK to the CHUTE UP EXIT (PL10.1.4) by moving it in the oppo-
site direction of the arrow.
2)
Install the CHUTE UP EXIT. (RRP10.3)
3)
Install the COVER EXIT 500 (PL10.1.1). (RRP10.1)
4)
Install the COVER RIGHT (PL1.1.4). (RRP1.2)
5)
Install the COVER LEFT (PL1.1.6). (RRP1.3)
6)
Install the COVER REAR (PL1.1.3). (RRP1.1)
There are 2 kinds of screws, make sure they are put in the right place.
7)
Install the COVER REAR 500 (PL10.2.21). (RRP10.9)
Chapter 3 Removal and Replacement Procedures (RRPs)
3 – 289