Removal
1)
Remove the COVER REAR 500/COVER REAR 250 (PL10.2.21/9.1.12). (RRP10.9/9.4)
2)
Remove the COVER REAR (PL1.1.3). (RRP1.1)
3)
Remove the COVER LEFT (PL1.1.6). (RRP1.3)
4)
Remove the COVER RIGHT (PL1.1.4). (RRP1.2)
5)
Remove the COVER EXIT 500 (PL10.1.1)/CHUTE ASSY EXIT 250 (Reference Only). (PL9.1.14)
(RRP10.1/9.7)
6)
Remove the 500 EXIT ASSY (PL10.1.2)/CHUTE LW EXT2 ASSY (PL9.1.2). (RRP10.2/9.1)
7)
Remove the COVER TOP (PL1.1.7). (RRP1.4)
8)
Remove the COVER FRONT (PL1.1.5). (RRP1.5)
9)
Remove the SHIELD PLATE LVPS (PL12.1.3). (RRP12.1)
10) Release the clamp of the HARNESS ASSY AC100V/AC200V from the clampers on the GEAR
ASSY HOUSING (PL11.1.3).
11) Disconnect the connector (P/J480) of the HARNESS ASSY AC100V/AC200V from the POWER
SWITCH.
12) Disconnect the connector (P/J48) of the HARNESS ASSY AC100V/AC200V from the LVPS
(PL12.1.5).
13) Release the clamp of the HARNESS ASSY AC100V/AC200V,
14) Remove the screw (silver with toothed washer, 6mm) securing the ground terminal of the HAR-
NESS ASSY AC100V/AC200V to the frame.
15) Pull out the HARNESS ASSY AC100V/AC200V from the hole at the rear of the frame.
16) Remove the POWER SWITCH from the frame.
Replacement
1)
Install the POWER SWITCH to the frame.
2)
Install the HARNESS ASSY AC100V/AC200V to the hole at the rear of the frame.
3)
Secure the ground terminal of the HARNESS ASSY AC100V/AC200V to the frame using the screw
(silver with toothed washer, 6mm).
4)
Secure the HARNESS ASSY AC100V/AC200V.
5)
Connect the connector (P/J48) of the HARNESS ASSY AC100V/AC200V to the LVPS (PL12.1.5).
6)
Connect the connector (P/J480) of the HARNESS ASSY AC100V/AC200V to the POWER
SWITCH.
7)
Secure the HARNESS ASSY AC100V/AC200V using the clampers of the GEAR ASSY HOUSING
(PL11.1.3).
8)
Install the SHIELD PLATE LVPS (PL12.1.3). (RRP12.1)
9)
Install the COVER FRONT (PL1.1.5). (RRP1.5)
10) Install the COVER TOP (PL1.1.7). (RRP1.4)
11) Install the 500 EXIT ASSY (PL10.1.2)/CHUTE LW EXT2 ASSY (PL9.1.2). (RRP10.2/9.1)
When installing, pull the CHUTE EXIT FUSER lever.
12) Install the COVER EXIT 500 (PL10.1.1)/CHUTE ASSY EXIT 250 (Reference Only). (PL9.1.14)
(RRP10.1/9.7)
13) Install the COVER RIGHT (PL1.1.4). (RRP1.2)
14) Install the COVER LEFT (PL1.1.6). (RRP1.3)
15) Install the COVER REAR (PL1.1.3). (RRP1.1)