Oki B6200 Maintenance Manual page 443

Hide thumbs Also See for B6200:
Table of Contents

Advertisement

Removal
1)
Remove the COVER REAR 500 (PL10.2.21). (RRP10.9)
2)
Remove the COVER REAR (PL1.1.3). (RRP1.1)
3)
Remove the COVER LEFT (PL1.1.6). (RRP1.3)
4)
Remove the COVER RIGHT (PL1.1.4). (RRP1.2)
5)
Remove the COVER EXIT 500 (PL10.1.1). (RRP10.1)
6)
Remove the 500 EXIT ASSY (PL10.1.2). (RRP10.2)
7)
Remove the 2 screws (gold tapping, 8mm) securing the CHUTE UP EXIT to the CHUTE LOW
EXIT.
8)
Separate the CHUTE UP EXIT and CHUTE LOW EXIT.
Replacement
1)
Remove the LINK GATE OCT (PL10.1.7) assembled into the removed CHUTE UP EXIT.
2)
Secure the CHUTE UP EXIT to the CHUTE LOW EXIT using the 2 screws (gold tapping, 8mm).
3)
Put the LINK GATE OCT under the 2 arms of the CHUTE UP EXIT as shown in figure 1, and turn it
in the direction of the arrow.
4)
Push the LINK GATE OCT in the direction of the arrow shown in the figure 2 as far as it will go.
After installing, make sure that the LINK GATE OCT is placed at the back side of
the GATE.
After installing, make sure that the tip of the LINK GATE OCT is placed under the
hook of the CHUTE LOW EXIT. (Note2)
After installing, make sure that the GATE moves when the LINK GATE OCT is
pushed in the direction of the arrow. (Note2)
5)
Install the 500 EXIT ASSY (PL10.1.12). (RRP10.2)
6)
Install the COVER EXIT 500 (PL10.1.1). (RRP10.1)
7)
Install the COVER RIGHT (PL1.1.4). (RRP1.2)
8)
Install the COVER LEFT (PL1.1.6). (RRP1.3)
9)
Install the COVER REAR (PL1.1.3). (RRP1.1)
There are 2 kinds of screws, make sure they are put in the right place.
10) Install the COVER REAR 500 (PL10.2.21). (RRP10.9)
Chapter 3 Removal and Replacement Procedures (RRPs)
(Note1)
3 – 279

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B6300

Table of Contents