FIP2.2 MAIN MOTOR (PL11.1.2)

Step
Possible causative parts:
MAIN MOTOR (PL11.1.2)
HARNESS ASSY LVPS (PL12.1.1)
LVPS (PL12.1.5)
HVPS/MCU (PL12.1.19)
Checking MAIN MOTOR
Remove EP CARTRIDGE.
1
Close COVER OPEN (PL1.1.2).
Does MAIN MOTOR rotate, when the power is turned ON?
Check by rotation sound of MAIN MOTOR.
2
Is the trouble eliminated?
Checking HARNESS ASSY LVPS for continuity (1)
Remove SHIELD PLATE LVPS. (RRP12.1)
3
Disconnect P/J41 from LVPS.
Disconnect P/J11 from HVPS/MCU.
Is each cable of P/J41 <=> P/J11 continuous?
Checking HARNESS ASSY LVPS for continuity (2)
Remove SHIELD PLATE LVPS. (RRP12.1)
4
Disconnect P/J42 from LVPS.
Disconnect P/J10 from HVPS/MCU.
Is each cable of P/J42 <=> P/J10 continuous?
Checking LVPS
5
Replace LVPS. (RRP12.3)
Is the trouble eliminated?
Checking HVPS/MCU
6
Replace HVPS/MCU. (RRP12.10)
Is the trouble eliminated?
Check
1 - 54
Chapter 1 Troubleshooting
Yes
Go to step 2.
Go to step 3.
End of work
Go to step 3.
Go to step 4.
HARNESS ASSY
Go to step 5.
HARNESS ASSY
End of work
Go to step 6.
Replace MAIN
End of work
(RRP11.2)
No
Replace
LVPS.
Replace
LVPS.
MOTOR.