Oki B6200 Maintenance Manual page 31

Hide thumbs Also See for B6200:
Table of Contents

Advertisement

Chain Link Fault Items
103
208 All Serial No. Mismatch
103
320 SEEPROM Fail
103
321 Backup SRAM Fail
ESS ROM DIMM #1 Not
103
331
Found
103
332 ESS Standard ROM Error
103
333 ASIC Fail
103
334 Standard Font ROM Error
103
335 Font ROM Not Found
103
337 ESS Standard RAM Error
103
338 Same Font ROMs Found
ROM DIMM of Another
103
339
Product Found
103
372 IOT sc S/W Fail
IOT Manager software
103
373
error
IOT IM DeviceDriver
103
374
software error
116
200 Main PWB IC Fail
116
201 HD Fail
M/C is not started
because a ProductCode
116
203
trouble is caused to HDD
when starting.
M/C is not started
because incorrect
116
204
capacity of HDD is
detected when formatting
HDD.
Conditions of detect/Methods of treatment
At least one of Serial No. which are maintained in three points become
wrong value.
Execute DC132 Serial No matching.
When it is not recovered yet, Replace ESS PWB or MCU PWB in
order. (Replacing both of them simultaneously is impossible.)
Writing to SEEPROM on ESS PWB is not available.
When it is not recovered by powering OFF and On, replace ESS PWB.
Writing to SRAM on ESS PWB is not available.
When it is not recovered by powering OFF and On, replace ESS PWB.
Extension ROM is not installed. (Option)
Install extension ROM.
If the trouble is not recovered by installing it, Replace ESS PWB.
Detect standard ROM(On board) error.
When it is not recovered by powering OFF and On, replace ESS PWB.
Internal process error is caused within ESS PWB.
When it is not recovered by powering OFF and On, replace ESS PWB.
Detect the trouble of ESS standard built in fonts ROM.
When it is not recovered by powering OFF and On, replace ESS PWB.
Font ROM is not built in.
If only the standard font ROM is built in, Replace ESS PWB.
If the option font ROM is installed, insert and remove theoption font
ROM.
When it is not recovered yet, replace the option font ROM.
Detect the error of ESS standard built in RAM.
When it is not recovered by powering OFF and On, replace ESS PWB.
Detect that the same font ROM is installed.
Check the font ROM.
If the trouble is not recovered, execute the followings.
Replace ESS PWB.
Detect that the ROM for other machine is installed.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
The trouble is caused to IC in ESS PWB.
When it is not recovered by powering OFF and On, replace ESS PWB.
HDD is not started because a physical trouble is caused to HDD when
starting.
When it is not recovered by powering OFF and On, execute the
follownings.
Execute HDD Test (DC355)
Replace HDD
Replace ESS PWB
HDD is not started because a ProductCode trouble is caused to HDD
when starting.
The possibility that it is formatted by wring product M/C is high.
Format HDD again.
Replace HDD.
HDD is formatted, but the incorrect HDD is connected or a trouble of
HDD is caused.
Format HDD again.
Replace HDD.
1 - 15
Chapter 1 Troubleshooting
Ref FIP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B6300

Table of Contents