Oki B6200 Maintenance Manual page 451

Hide thumbs Also See for B6200:
Table of Contents

Advertisement

Removal
1)
Remove the COVER REAR 500 (PL10.2.21). (RRP10.9)
2)
Remove the COVER REAR (PL1.1.3). (RRP1.1)
3)
Remove the COVER LEFT (PL1.1.6). (RRP1.3)
4)
Remove the COVER RIGHT (PL1.1.4). (RRP1.2)
5)
Remove the COVER EXIT 500 (PL10.1.1). (RRP10.1)
6)
Remove the CHUTE UP EXIT (PL10.1.4). (RRP10.3)
7)
Disconnect the connector (P/J290) of the HARNESS ASSY EXIT SNR (PL10.1.27) from the SEN-
SOR FULL STACK.
8)
Release the hooks of the SENSOR FULL STACK, and remove the SENSOR FULL STACK from
the CHUTE LOW EXIT (PL10.1.21).
Replacement
1)
Install the SENSOR FULL STACK to the CHUTE LOW EXIT (PL10.1.21).
2)
Connect the connector (P/J290) of the HARNESS ASSY SNR (PL10.1.27) to the SENSOR FULL
STACK.
3)
Install the CHUTE UP EXIT (PL10.1.4). (RRP10.3)
4)
Install the COVER EXIT 500 (PL10.1.1). (RRP10.1)
5)
Install the COVER RIGHT (PL1.1.4). (RRP1.2)
6)
Install the COVER LEFT (PL1.1.6). (RRP1.3)
7)
Install the COVER REAR (PL1.1.3). (RRP1.1)
There are 2 kinds of screws, make sure they are put in the right place.
8)
Install the COVER REAR 500 (PL10.2.21). (RRP10.9)
Chapter 3 Removal and Replacement Procedures (RRPs)
3 – 287

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B6300

Table of Contents