Removal
1)
Open the COVER OPEN (PL1.1.2).
2)
Disconnect the connector (P/J220) of the SENSOR TONER from the HARNESS ASSY TONER 1
(PL5.1.50).
3)
Release the holdings of the harness of the SENSOR TONER from 2 clampers.
4)
Release 2 hooks of the HOLDER-D (PL5.1.47), and remove the SENSOR TONER from the
HOLDER-D by turning it in the direction of the arrow.
When removing the SENSOR TONER, be careful not to lose the SPRING TONER
(PL5.1.48).
Replacement
1)
Install the SENSOR TONER to the HOLDER-D (PL5.1.47) by turning it in the opposite direction of
the arrow, and secure it using 2 hooks.
When installing the SENSOR TONER, put the SPRING TONER on the boss of the
HOLDER-D, and then install the SENSOR TONER on it.
2)
Secure the harness of the SENSOR TONER using the 2 clampers.
3)
Connect the connector (P/J220) of the SENSOR TONER to the HARNESS ASSY TRAY 1
(PL5.1.50).
4)
Close the COVER OPEN (PL1.1.2).
Chapter 3 Removal and Replacement Procedures (RRPs)