34PPM
Removal
1)
Remove the COVER REAR 500 (PL10.2.21). (RRP10.9)
2)
Remove the COVER REAR (PL1.1.3). (RRP1.1)
3)
Remove the FUSER ASSY (PL8.1.20). (RRP8.8)
4)
Remove the COVER LEFT (PL1.1.6). (RRP1.3)
5)
Remove the COVER RIGHT (PL1.1.4). (RRP1.2)
6)
Remove the COVER EXIT 500 (PL10.1.1). (RRP10.1)
7)
Remove the 500 EXIT ASSY (PL10.1.2). (RRP10.2)
8)
Remove the COVER TOP (PL1.1.7). (RRP1.4)
9)
Remove the COVER FRONT (PL1.1.5). (RRP1.5)
10) Remove the BTR ASSY (PL8.1.21). (RRP8.10)
11) Remove the DUCT FRONT (PL8.1.4). (RRP8.2)
12) Remove the ROS ASSY (PL8.1.1). (RRP8.1)
Never give any impact to the ROS ASSY with a screwdriver or other tools.
13) Remove the SHIELD PLATE ROS (PL8.1.3). (RRP8.3)
14) Remove the GUIDE TRAY LEFT (PL7.1.7). (RRP7.8)
15) Remove the MOTOR COVER (PL11.1.1). (RRP11.1)
16) Remove the SHIELD PLATE LVPS (PL12.1.3). (RRP12.1)
17) Remove the GUIDE CRU LEFT (PL8.1.15). (RRP8.4)
18) Remove the COVER GUIDE CRU (PL8.1.16) and HARNESS ASSY FUSER (PL8.1.17) from the
GUIDE CRU LEFT. (RRP8.7)
19) Remove the LEVER LINK and LINK GEAR 3.
Replacement
1)
Assemble the LEVER LINK and LINK GEAR 3 as shown in the figure, and install them to the
GUIDE CRU LEFT (PL8.1.15).
2)
Install the COVER GUIDE CRU (PL8.1.16) and HARNESS ASSY FUSER (PL8.1.17) to the
GUIDE CRU LEFT. (RRP8.7)
3)
Install the GUIDE CRU LEFT. (RRP8.4)
When installing, make sure that the LEVER LINK (PL8.1.29) is attached to the
GUIDE CRU LEFT.
After installing the GUIDE CRU LEFT, touch the LINK GEAR 3 with your finger.
Make sure that your finger can feel the LINK GEAR 3 move inward, when the LEVER
LINK is pulled up.
4)
Install the SHIELD PLATE LVPS (PL12.1.3). (RRP12.1)
5)
Install the MOTOR COVER (PL11.1.1). (RRP11.1)
6)
Install the GUIDE TRAY LEFT (PL7.1.7). (RRP7.8)
7)
Install the he SHIELD PLATE ROS (PL8.1.3). (RRP8.3)
8)
Install the ROS ASSY (PL8.1.1). (RRP8.1)
Never give any impact to the ROS ASSY with a screwdriver or other tools.
9)
Install the DUCT FRONT (PL8.1.4). (RRP8.2)
10) Install the COVER FRONT (PL1.1.5). (RRP1.5)