FIP2.16 CLUTCH ASSY PH (PL5.1.21, PL6.1.21, PL7.1.20)

Step
Possible causative parts:
CLUTCH ASSY PH (PL5.1.21, PL6.1.21, PL7.1.20)
HARNESS ASSY TRAY1 (PL5.1.37)
HARNESS ASSY TRAY2 (PL6.1.36, PL7.1.36)
HARNESS ASSY CHUTE (PL12.1.17)
HVPS/MCU (PL12.1.19)
LVPS (PL12.1.5)
Checking HARNESS ASSY CHUTE for continuity
Disconnect P/J24 from HVPS/MCU.
Are the following continuous normally?
J24-13 <=> J245-6
1
J24-12 <=> J245-7
J24-5 <=> J248-1
J24-4 <=> J248-2
Checking HARNESS ASSY TRAY1 and TRAY2 for
continuity
Remove CLUTCH ASSY PH.
Disconnect P/J245 or P/J248.
Are the following continuous normally?
2
P/J245-8 <=> P/J242-1
P/J245-7 <=> P/J242-2
P/J248-5 <=> P/J247-1
P/J248-4 <=> P/J247-2
Checking the resistance of CLUTCH ASSY PH
Is each resistance of the wirewound resistor between
3
P/J242-1 <=> P/J242-2, and P/J247-1 <=> P/J247-2 of
CLUTCH ASSY PH, 172 ohm +/-10% (at 20 °C)?
Checking HVPS/MCU for continuity
Disconnect P/J24 and P/J10 from HVPS/MCU.
4
Are the following continuous normally?
J24-12 <=> J10-1
J24-4 <=> J10-1
Check
1 - 72
Chapter 1 Troubleshooting
Yes
Go to step 2.
HARNESS ASSY
Go to step 3.
HARNESS ASSY
TRAY1 or TRAY2.
Replace CLUTCH
Go to step 4.
ASSY PH.
(RRP5.6, 6.5, 7.5)
Go to FIP2.1
HVPS/MCU.
LVPS.
(RRP12.10)
No
Replace
CHUTE.
Replace
Replace