Chain Link Fault Items
BMLinkS/Print Service
116
363
Software Fail
116
365 Spool Fatal Error
Print Utilityoperational
116
366
falure
116
367 Parallel I/F S/W Fail
116
368 Dump Print Fatal Error
116
370 XJCL S/W Fail
PCL Decomposer S/W
116
371
Fail
116
372 P-Formatter Fatal Error
116
373 Dynamic DNS Fatal Fail
116
374 Auto Switch Fail
116
376 Port 9100 S/W Fail
116
377 Video DMA Fail
MCR(Mail Contents
116
378
Requester) S/W Fatal Fail
MCC(Mail Contents
116
379
Creator)S/W Fatal Fail
116
385 IDC S/W Fail
When requiring HDD,
116
388
HDD is not installed.
When requiring additional
116
389
RAM, the additional RAM
is not installed.
116
395 USB Fatal Error
116
396 Mail IO Fatal Error
Conditions of detect/Methods of treatment
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
When it is not recovered by powering OFF and On, replace ESS PWB
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
When it is not recovered by powering OFF and On, replace ESS PWB
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
The internal process error is caused in ESS PWB.
When it is not recovered by powering OFF and On, replace ESS PWB
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
An error is caused when processing the software in ESS PWB, and the
process cannot be continued after that.
Replace ESS PWB.
HDD is required to the configuration, but HDD is not installed.
Check the connection of P310 on ESS PWB.
Additional RAM is required to the configuration (with HDD), but the
additional RAM is not installed.
Check whether the additional RAM is installed completely.
The serious error of USB is caused.
An error is caused when processing the software, and the process
cannot be continued after that.
Replace ESS PWB.
The serious error of Mail IO is caused.
An error is caused when processing the software, and the process
cannot be continued after that.
Replace ESS PWB.