TRBL
SHTG
Troubleshooting the power unit
using the diagnostic flash indicator
1. Connect the special service tool to the
outboard motor as shown.
L/W
NOTE:
When performing this diagnosis, all of the
electrical wires must be properly connected.
Diagnostic flash indicator B:
90890-06865
2. Start the engine and let it idle.
3. Check the flash pattern of the special
service tool to determine if there are any
malfunctions.
• Normal condition
(no defective part or irregular process-
ing is found)
• Single flash is given every 4.95 sec-
onds.
a: Light on, 0.33 second
b: Light off, 4.95 seconds
9-15
Troubleshooting
S6P29030E
• Trouble code indication
Example: The illustration indicates
code numbers 23 and 113.
a: Light on, 0.33 second
b: Light off, 4.95 seconds
c: Light off, 0.33 second
d: Light off, 1.65 seconds
1
1
c
d
d
a
a
a
4. If a flash pattern listed in the trouble code
chart is displayed, check the malfunction-
ing part according to the flash pattern.
3
b
a
a
S6P29040
6P23H11