15 Define the following parameters:
SNMP - Security
Field
Send Authentication
Trap
Accept Host Community
Name
Accept SNMP Packets
from all Host
Accept SNMP Packets
from the following Hosts
User Name
Security Level
Authentication Protocol
Authentication
Password
Privacy Protocol
Privacy Password
Engine ID
Polycom®, Inc.
Description
Select this check box to send a message to the SNMP Manager
when an unauthorized query is sent to the MCU. When cleared, no
indication will be sent to the SNMP Manager.
Enter the string added to queries that are sent from the SNMP
Manager to indicate that they were sent from an authorized source.
Note: Queries sent with different strings will be regarded as a
violation of security, and, if the Send Authentication Trap check box
is selected, an appropriate message will be sent to the SNMP
Manager.
Select this option if a query sent from any Manager terminal is valid.
When selected, the Accept SNMP Packets from These Hosts option
is disabled.
Lists specific Manager terminals whose queries will be considered
as valid. This option is enabled when the Accept SNMP Packets
from any Host option is cleared.
Enter a User Name of up to 48 characters
Default: Empty
Select a Security Level from the drop-down menu.
Range: No Auth, No Priv; Auth, No Priv; Auth, Priv
Default: Auth, Priv
Select the authentication protocol
Range: MD5, SHA
Default: MD5
Enter an Authentication
Password.
Range: 8 - 48 characters
Default: Empty
Select a Privacy Protocol.
Range: DES, AES
Default: DES
Enter a Privacy Password.
Range: 8 - 48 characters
Default: Empty
Enter an Engine ID to be used for
both the Agent and the Trap.
Default: Empty
Administration and Utilities
These fields are enabled if
Authentication is selected
in the Security Level field.
These fields are enabled if
Privacy is selected in the
Security Level field.