Traps
Three types of traps are sent as follows:
● ColdStart trap. This is a standard trap which is sent when the MCU is reset.
An Example of a ColdStart Trap
coldStart notification received from: 172.22.189.154 at 5/20/2007
7:03:12 PM
Time stamp: 0 days 00h:00m:00s.00th
Agent address: 172.22.189.154 Port: 32774 Transport: IP/UDP
Protocol: SNMPv2c Notification
Manager address: 172.22.172.34 Port: 162 Transport: IP/UDP
Community: public
Enterprise: enterprises.8072.3.2.10
Bindings (3)
● Authentication failure trap. This is a standard trap which is sent when an unauthorized community
tries to enter.
An Example of an Authentication Failure Trap
authentication Failure notification received from: 172.22.189.154 at
5/20/2007 7:33:38 PM
Time stamp: 0 days 00h:30m:27s.64th
Agent address: 172.22.189.154 Port: 32777 Transport: IP/UDP
Protocol: SNMPv2c Notification
Manager address: 172.22.172.34 Port: 162 Transport: IP/UDP
Community: public
Enterprise: enterprises.8072.3.2.10
Bindings (3)
● Alarm Fault trap. The third trap type is a family of traps defined in the POLYCOM-RMX-MIB file,
these traps are associated with the Collaboration Server active alarm and clearance (proprietary
SNMP trap).
An Example of an Alarm Fault Trap