Polycom RealPresence 1500 Administrator's Manual page 1132

Collaboration server
Hide thumbs Also See for RealPresence 1500:
Table of Contents

Advertisement

Using the RMX Manager:
c In the MCUs list, select the RMX to be updated.
d In MCU Properties, change the Port number from 443 to 80.
e Click OK.
f
In the MCUs list, select the RMX to be updated.
g Right-click in the MCUs list entry and select Connect.
h Click Accept to accept the warning banner.
i
Enter an administrator Username and Password.
j
Click OK.
Step 3: Open the Certification Repository and Update the CRL files
a On the RMX menu, click Setup > RMX Secured Communication > Certification Repository.
b Click the CRL tab.
c Click Add.
d In the Install File dialog box, select the DER or PEM format depending on which file format was
chosen in Step 1 of this procedure.
e Click the Browse button to navigate to the folder on the workstation where you saved the CRL
files in Step 1 of this procedure.
f
Select the CRL file that you want to upload.