Appendix B - Active Alarms

Active Alarms
Alarm Code
A matching activation key is required.
To cancel the upgrade process, reset
the Collaboration Server
A new activation key was loaded.
Reset the system.
A new version was installed. Reset the
system.
Alarm generated by a Central
Signaling component
Alarm generated by an internal
component
Allocation mode was modified
Automatic reset is unavailable in Safe
Mode
Backup of audit files is required
Backup of CDR files is required
Backup of log files is required
Bios version is not compatible with
Ultra Secure Mode.
Card configuration event
Card failed to switch to Enhanced
Secure Mode
Polycom®, Inc.
Alarm Description
The system upgrade requires that a valid activation key be entered. If
none is available, resetting the Collaboration Server will cancel the
upgrade and return the Collaboration Server to the previous version.
A new activation key was loaded: Reset the MCU.
A new version was installed: Reset the MCU.
A system alert was generated by a component of the Central Signaling.
A system alert was generated by an internal system component.
The system switches to safe mode if many resets occur during startup. To
prevent additional resets, and allow the system to complete the startup
process the automatic system resets are blocked.
If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the
user is alerted that audit files need to be backed up.
If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the
user is alerted that CDR files need to be backed up.
If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the
user is alerted that log files need to be backed up.
The current BIOS version is not compatible with Ultra Secure Mode
(ULTRA_SECURE_MODE=YES).
Card failure occurred when the system was set to Ultra Secure Mode
(ULTRA_SECURE_MODE=YES).