9 This process may take some time. Click Stop Running Test to end all the diagnostic tests. The
MCU completes the current test running and then stops all remaining tests.
10 The Diagnostics Mode can be exited by pressing the yellow System Reset icon. The Collaboration
Server then resets.
Diagnostics Monitoring
A hardware component's test status can be viewed in the Diagnostics Test Monitoring section before, during
and after tests have been initiated. Test results will only be displayed after tests are completed. The
Diagnostic Tests Monitoring section is comprised of three tabs: MCU Monitor, Cards Monitor and Error
Buffer, which are further described below.
MCU Monitor
The MCU Monitor tab lists the status of all the cards that can be tested in Diagnostic Mode. Described below
are the columns:
Tests Monitoring - MCU Monitor Parameters
Column
Card
Pass
Fail
Status
Cards Monitor
The Cards Monitor tab displays the status of the selected tests being run on the currently viewed card, i.e.
slot 5, described below.
Polycom®, Inc.
Description
The card's slot number, i.e. 5 - slot where the RTM IP card resides.
Indicates the number of tests that the card passed successfully.
Indicates the number of tests that the card failed.
The card's current test status: No test running or Test in progress.