Figure 11

Rack-Mount installation

60
SAN32M-1 Installation and Service Manual
c. Using a pencil or other pointed instrument, set the medium-
dependent interface (MDI) switch on the top and middle hubs
to MDI (in). Set the MDI switch on the bottom hub to MDIX
(out). The configuration is shown in

Patch cable and MDI selector configuration

5. Connect the power cord to the receptacle at the rear of each hub
and to an AC power strip (a power strip is provided with the
optional management server). Use an 18-inch electrical extension
cord (provided) if required.
6. Connect the AC power strip to a facility power outlet. Power for
each hub switches on when the strip is connected to facility AC
power.
7. Inspect the front panel of each hub. Ensure each green Power
light-emitting diode (LED) illuminates.
Perform the following steps to install and configure up to three
Ethernet hubs in an equipment cabinet or a customer- supplied
19-inch equipment rack. A pointed instrument (pencil tip or bent
paper clip), #2 Phillips screwdriver, and 1/8-inch Allen wrench are
required.
Figure 11
on page 60.