IBM TotalStorage SAN32M-1 Installation And Service Manual page 302

Hide thumbs Also See for TotalStorage SAN32M-1:
Table of Contents

Advertisement

270
SAN32M-1 Installation and Service Manual
Segmentation Reason
Incompatible operating parameters.
Duplicate domain IDs.
Incompatible zoning configurations.
Build fabric protocol error.
No principal switch.
No response from attached switch.
7
As indicated by an event code 052, a minor internal operating error
was detected by the management server subsystem. The error
caused management server databases to be re-initialized to an
empty state. As a result, a disruptive server logout and login occurred
for all attached devices. All attached devices resume operation after
management server login.
Perform the data collection procedure and return the CD to IBM for
analysis.
8
As indicated by an event code 062, the fabric controller software
detected a path within the connected multiswitch fabric that traverses
more than three interswitch links (ISLs or hops). Fibre Channel
frames may persist in the fabric longer than timeout values allow.
Advise the customer of the problem and work with the system
administrator to reconfigure the fabric so the path between any two
fabric switches does not traverse more than three hops.
Did fabric reconfiguration solve the problem?
NO
YES
The switch and connected multiswitch fabric appear
operational.
Contact the next level of support.
9
As indicated by an event code 063, the Fabric Controller software
detected an:
Action
Go to
step
12.
Go to
step
13.
Go to
step
14.
Go to
step
15.
Go to
step
20.
Go to
step
17.

Advertisement

Table of Contents
loading

Table of Contents