Figure 100
162
SAN32M-1 Installation and Service Manual

Fabric Parameters View

a. At the R_A_TOV field, type a value between 10 through 1200
tenths of a second (one through 120 seconds). Ten seconds
(100) is the recommended value. The R_A_TOV value must
exceed the E_D_TOV value.
b. At the E_D_TOV field, type a value between 2 through 600
tenths of a second (0.2 through 60 seconds). Two seconds (20)
is the recommended value.
NOTE: Fabric elements must be set to the same R_A_TOV and
E_D_TOV values. An ISL between fabric elements with different
values segments and prevents communication.
c. Select from the Switch Priority drop-down list to designate the
fabric's principal switch. The principal switch is assigned a
priority of 1 and controls the allocation and distribution of
domain IDs for all fabric elements (including itself). Available
selections are Default, Principal, and Never Principal.
Principal is the highest priority setting, Default is next, and
Never Principal is the lowest. At least one switch in a fabric
must be set as Principal or Default. If all switches are set to
Never Principal, all ISLs segment.
d. Select from the Interop Mode drop-down list to set the product
operating mode. This setting affects the management mode
and does not affect port operation. Available selections are: