10-100 km Configuration - a user-specified state for the port (On
or Off), configured through the Configure Ports dialog box.
LIN Alerts Configuration - a user-specified state for the port (On
or Off), configured through the Configure Ports dialog box.
Beaconing - user-specified for the port (On or Off). When
beaconing is enabled, a yellow triangle appears adjacent to the
status field.
Link Incident - If no link incidents are recorded, None appears in
the status field. If a link incident is recorded, a summary appears
describing the incident, and a yellow triangle appears adjacent to
the status field. Valid summaries are:
— Implicit incident.
— Bit-error threshold exceeded.
— Link failure - loss of signal or loss of synchronization.
— Link failure - not-operational primitive sequence received.
— Link failure - primitive sequence timeout.
— Link failure - invalid primitive sequence received for the
current link state.
Operational State - the state of the port (Online, Offline, Beaconing,
Invalid Attachment, Link Incident, Link Reset, No Light, Not
Operational, Port Failure, Segmented E_Port, or Testing). A yellow
triangle appears adjacent to the status field if the port is in a
non-standard state that requires attention. A red and yellow
blinking diamond appears adjacent to the status field if the port
fails.
Reason - If the E_Port segments while attempting to form a
multiswitch fabric, a summary appears describing the reason for
segmentation. Valid summaries are:
— Incompatible operating parameters.
— Duplicate domain ID(s).
— Incompatible zoning configurations.
— Build fabric protocol error.
— No principal switch.
— No response from attached switch.
— Exchange link protocol (ELP) retransmission failure timeout.