This displays when port diagnostics is run on a port in an inactive
state.
Run the diagnostics on an active port.
Port speeds cannot be configured at a higher rate than the
director/switch speed.
This displays when you configure a port to 2 GB/sec and the switch
speed is set to 1 Gb/sec.
Set the port speed to 1 Gb/sec in the Configure Ports dialog box.
R_A_TOV must be greater than E_D_TOV.
R_A_TOV must be greater than E_D_TOV.
Change one of the values so that R_A_TOV is greater than E_D_TOV.
Resource is unavailable.
The specified operation cannot be performed because the product is
unavailable.
Verify that the EFC Server-to-product link is up. If the link is up, the
EFC Server may be busy. Try the operation again later.
Send firmware failed.
Send firmware operation has failed.
Retry the operation. If the condition persists, contact support
personnel.