h. Configure the Port Settings parameters as follows:
— Bits per second - 57600.
— Data bits - 8.
— Parity - None.
— Stop bits - 1.
— Flow control - Hardware.
When the parameters are set, click OK. The HyperTerminal
window displays.
i. At the C> prompt, type the user-level password (the default is
password) and press Enter. The password is case sensitive.
The HyperTerminal window displays with software and hardware
version information for the switch, and a C> prompt at the bottom
of the window.
j. At the C> prompt, type the displaylog command and press
Enter. The HyperTerminal window displays with the event log
(from switch NV-RAM) listed.

Hyperterminal window - event log

Figure 139
k. If listed in the REAS column, record the event code 433.
Chapter 3: Diagnostics
241