Figure 168
308
SAN32M-1 Installation and Service Manual
FRU list view
To open the FRU List View from the Hardware View, click View and
select FRU List. The FRU List View contains the following columns:
FRU -
an acronym representing the FRU type. FRU acronyms
are:
— SFP
- Small form factor pluggable (SFP) optical transceiver.
Chassis slots for SFPs inserted in a port are 0 through 31. The
SFPs are FRUs.
— PWR
- power supply. Chassis slots for redundant power
supplies are 0 and 1. The power supplies are FRUs.
— FAN -
cooling fan. Chassis slots for redundant fans are 0 (fan
FRU assembly) and 1 through 4 (cooling fans). The cooling
fans are FRUs.
— CTP -
control processor (CTP) card. The chassis slot is 0. The
CTP card is not a FRU.
— THM -
thermal sensor. The chassis slot is 0 (on the CTP
card). The thermal sensor is not a FRU.

Advertisement

Table of Contents
loading

Table of Contents