Event Code: 061
Message:
Fabric Controller database found to be invalid
Severity:
Minor
Explanation:
Following an IML, CTP hot-plug, CTP failover, or LIC load, a Fabric Controller database failed its validation. All
Fabric Services databases are initialized to an empty state resulting in a momentary loss of inter-switch
communications.
Action:
Perform the data collection procedure for the switch using the EFC Manager, and return the CD to IBM for
analysis.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 062
Message:
Maximum interswitch hop count exceeded
Severity:
Informational
Explanation:
The Fabric Controller software has detected that a path to another switch in the fabric traverses more than seven
interswitch links ('hops'). This may result in frames persisting in the fabric longer than the Fibre Channel standard
timeout values allow.
Action:
If possible, reconfigure the fabric so that the path between any two switches traverses no more than seven
interswitch links.
Event Data:
Byte 0 = domain ID of the switch more than seven hops away.
Bytes 1 - 3 = reserved.
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
EFC Server
E-Mail
Call-Home
Appendix B: Event code tables
Host
Sense Info
Link Incident
Host
Sense Info
Link Incident