Event Code: 605
Message:
SBAR module revision not supported
Severity:
Minor
Explanation:
The specified SBAR module is not recognized by the existing firmware. The SBAR module will appear uninstalled
to system software.
Action:
Ensure that the switch model supports the operating firmware. If the firmware supports the model, perform the
data collection procedure for the switch using the EFC Manager. If the problem persists following a system
power-on reset, replace the switch and return the switch and the CD to IBM for analysis and repair.
Event Data:
Byte 0 = Slot position
Bytes 4-7 = Elapsed millisecond tick counter
Bytes 8-9: = Detected Module identifier
Distribution: