IBM TotalStorage SAN32M-1 Installation And Service Manual page 514

Hide thumbs Also See for TotalStorage SAN32M-1:
Table of Contents

Advertisement

Event Code: 810
Message:
High temperature warning (CTP thermal sensor)
Severity:
Major
Explanation:
The CTP thermal sensor has detected that the "warm" temperature threshold level has been surpassed.
Action:
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to IBM for analysis. Perform a system power-on reset. If the problem persists, replace
the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 811
Message:
Critically hot temperature warning (CTP thermal sensor)
Severity:
Major
Explanation:
The CTP thermal sensor has detected that the "hot" temperature threshold level has been surpassed.
Action:
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to IBM for analysis. Perform a system power-on reset. If the problem persists, replace
the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
482
SAN32M-1 Installation and Service Manual
System
Event Log
Error
Indicator
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
EFC Server
E-Mail
Call-Home
Host
Sense Info
Link Incident
Host
Sense Info
Link Incident

Advertisement

Table of Contents