Event Code: 510
Message:
SFP optics hot-insertion initiated
Severity:
Informational
Explanation:
The hot insertion of a Small Form Factor pluggable optics transceiver has been detected. If the amber LED stays
illuminated after the insertion of the new optic transceiver, see the Port Failure event (506).
Action:
No action required.
Event Data:
Byte 0 = Slot position (port number)
Bytes 4-7 = Elapsed millisecond tick count.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 512
Message:
SFP optics nonfatal error
Severity:
Minor
Explanation:
A Small Form Factor pluggable optics module nonfatal failure has been detected by the system software.
Action:
Replace the Small Form Factor optics module with a working module of the same type.
Event Data:
Byte 00 = Port number (00-8F)
Byte 01 = Reason code
00 = Read of VPD data from optic component failed
Bytes 04-07 = Elapsed millisecond tick count
Distribution:
Switch
Nonvolatile
System
Event Log