TC63 AT Command Set
18.4 AT+CLVL
18.4

AT+CLVL Loudspeaker volume level

Syntax
Test Command
AT+CLVL=?
Response(s)
+CLVL: (list of supported<level>s)
OK
Read Command
AT+CLVL?
Response(s)
+CLVL:
<level>
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CLVL=<level>
Response(s)
OK
ERROR
+CME ERROR: <err>
Reference(s)
GSM 07.07
Parameter Description
(num)
<level>
Loudspeaker Volume Level
(D)
0...4
Notes
The write command can only be used in audio mode 2 - 6.
The values of the volume steps are specified with the parameters
brate>[4] of the
AT^SNFO
As an alternative to AT+CLVL, you can use
used by both commands.
<outStep>
Any change to
<level>
(or <outStep>) and then select another mode with AT^SNFS, the same step will be applied.
<level>
The only exception is audio mode 1 which is fixed to <level>=4 (or accordingly <outStep>=4).
(or <outStep>) is stored non-volatile when the ME is powered down with
<level>
AT+CFUN=1,1.
TC63_ATC_V00.490
Confidential / Draft - Do not copy
PIN
!
command.
AT^SNFO
(or <outStep>) takes effect in audio modes 2 to 6. That is, when you change
Page 413 of 501
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
%
%
%
%
<outCalibrate>[0],...<outCali-
and AT^SNFV. The parameter
s
Last
%
%
!
%
!
is identical with
<level>
or reset with
AT^SMSO
5/24/05