At^spbg Display Phonebook Entries In Alphabetical Order - Siemens TC63 Command Set

Cellular engine
Table of Contents

Advertisement

TC63 AT Command Set
17.9 AT^SPBG
17.9

AT^SPBG Display phonebook entries in alphabetical order

sorts the entries of the current phonebook in alphabetical order by name (the first six characters mat-
AT^SPBG
ter). The sort order is described in Section 17.1,
There are two ways to use AT^SPBG:
If the optional parameter
bered. As these numbers are not identical with the location numbers stored in the various phonebooks
can be used for reading only. For example, it helps you find entries starting with matching charac-
AT^SPBG
ters. Do not use the serial numbers to dial out or modify entries.
If parameter <RealLocReq>=1 is given by the write command, the response parameter
tionally appended to each entry indicates the actual location number. This number can be used for editing
with
or dialing with ATD><mem><n>. The first index number of each entry is only the serial number
AT+CPBW
of the sorted list.
Before using the
AT^SPBG
the active pohonebook (refer to test command parameter <used>). The test command also includes the param-
eters
and <tlength>. Note that if SIM storage is selected the length may not be available. If stor-
<nlength>
age does not offer format information, the format list should be empty parenthesises.
Syntax
Test Command
AT^SPBG=?
Response(s)
^SPBG: (1-<used>), <nlength>,
OK
ERROR
+CME ERROR
Write Command
AT^SPBG=<index1>[, <index2>][, <RealLocReq>]
Response(s)
[^SPBG: <index1>, <number>, <type>, <text>[, <location>]]
[^SPBG: <index2>, <number>, <type>, <text>[, <location>]]
OK
ERROR
+CME ERROR
Reference(s)
SIEMENS
Parameter Description
(num)
<index1>
First index number in the sorted list where to start reading. The supported range is given in the test command
response.
If <index 1> exceeds the upper bound <used>, "+CME ERROR: "invalid index" will be returned.
(num)
<index2>
Last index number in the sorted list where to stop reading. The supported range is given in the test command
response.
If
is not given via write command, only the entry located at
<index2>
If both
and
<index1>
<index2>
of entries will be output and terminated with OK.
If
exceeds the range indicated by the test command parameter <used>, the list of entries will be
<index2>
output but terminated with a "+CME ERROR: "invalid index".
TC63_ATC_V00.490
Confidential / Draft - Do not copy
Sort Order for
equals 0 or is omitted the sorted entries will be sequentially num-
<RealLocReq>
write command it is recommended to query the number of records currently stored in
<tlength>
are in the range indicated by the test command parameter <used>, the list
Page 404 of 501
Phonebooks.
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
%
%
%
%
<index1>
s
<location>
%
%
%
!
will be displayed.
addi-
Last
%
!
5/24/05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents