2.14 AT^SCFG
+CMGW: 1
OK
AT^SCFG="AutoExec",1,0,0,0,"AT+CMSS=1"
^SCFG: "AutoExec","1","0","0","0","at+cmss=1"
^SCFG: "AutoExec","0","1","0","0","","000:00:00","000:00:00"
^SCFG: "AutoExec","0","1","1","0","","000:00:00","000:00:00"
^SCFG: "AutoExec","0","1","2","0","","000:00:00","000:00:00"
OK
If a DTR activation has occured the ME issues the URC
command; the message reference in this case:
^SCFG:"AutoExec",0,0,1,0,"AT+CMSS=1"
OK
+CMSS: 16
EXAMPLE 2
Configure TC63 to perform a reset every 10 hours. The execution of the reset command shall be deferred
until after any calls have ended.
For details regarding software controlled power down refer to
AT^SCFG="AutoExec",1,1,2,5,"AT+CFUN=0,1","010:00:00"
...
OK
After ten hours:
^SCFG:"AutoExec",1,1,2,5,"AT+CFUN=0,1"
OK
SYSSTART
EXAMPLE 3
Switch off the ME after three minutes without restarting it.
For details regarding software controlled power down refer to
AT^SCFG="AutoExec",1,1,2,0,"AT^SMSO","000:03:00"
...
OK
After three minutes:
^SCFG:"AutoExec",0,1,2,0,"AT^SMSO"
^SMSO: MS OFF
^SHUTDOWN
EXAMPLE 4
Deactivate a timer-driven Autoexec function configured at
matic reset or the automatic switch-off functions configured in the preceding examples):
AT^SCFG="AutoExec",0,1,2
...
OK
EXAMPLE 5
Usage of "URC/Ringline" and "URC/Datamode/Ringline":
AT+CSCS="GSM"
OK
AT^SCFG?
...
^SCFG:"URC/Datamode/Ringline","off"
TC63_ATC_V00.490
Confidential / Draft - Do not copy
Confirms that message is stored to first location.
Enable execution on next DTR activation.
"^SCFG:
" followed by the response of the executed
Confirms that AT+CMSS=1 has been issued.
AT+CFUN
Confirms that AT+CFUN=0,1 has been issued.
TC63
has
"^SYSSTART" URC will not appear if autobauding is
enabled.
AT+CFUN
Indicates that AT^SMSO was successfully executed.
The ME enters the POWER DOWN mode.
<AutoExecIndex>
Switch to GSM character set.
Query all parameters.
While the TA-TE link is reserved URCs will be indi-
cated by BREAK.
Page 63 of 501
s
and AT^SMSO.
restarted.
Remember
and AT^SMSO.
2 (such as the periodic auto-
that
the
5/24/05