1.4 AT Command Syntax

1.4
AT Command Syntax
The "AT" or "at" prefix must be set at the beginning of each command line. To terminate a command line enter
. Commands are usually followed by a response that includes "
<CR>
out this document, only the responses are presented,
Table 1.4:
Types of AT commands and responses
AT command type
Test command
Read command
Write command
Exec(ution) command
1.4.1

Using Parameters

Optional parameters are enclosed in square brackets. If optional parameters are omitted, the current settings
are used until you change them.
Optional parameters or subparameters can be omitted unless they are followed by other parameters. If you
want to omit a parameter in the middle of a string it must be replaced by a comma. See also example 1.
A parameter value enclosed in square brackets represents the value that will be used if an optional parameter
is omitted. See also example 2.
When the parameter is a character string, e.g.
marks, e.g. "Charlie Brown" or "+49030xxxx". Symbols in quotation marks will be recognized as strings.
All spaces will be ignored when using strings without quotaton marks.
It is possible to omit the leading zeros of strings which represent numbers.
If an optional parameter of a V.250 command is omitted, its value is assumed to be 0.
Example 1: Omitting parameters in the middle of a string
AT+CCUG?
+CCUG: 1,10,1
OK
AT+CCUG=,9
OK
AT+CCUG?
+CCUG: 1,9,1
OK
Example 2: Using default parameter values for optional parameters
AT+CFUN=7,0
OK
AT+CFUN?
+CFUN: 7
OK
AT+CFUN=
OK
+CFUN: 1
OK
TC63_ATC_V00.490
Confidential / Draft - Do not copy
Syntax
Function
AT+CXXX=?
The mobile equipment returns the list of parameters and value
ranges set with the corresponding Write command or by internal
processes.
AT+CXXX?
This command returns the currently set value of the parameter or
parameters.
AT+CXXX=<...>
This command sets user-definable parameter values.
AT+CXXX
The execution command reads non-variable parameters deter-
mined by internal processes in the GSM engine.
<text>
Query current setting
Set only the middle parameter
Query new setting
Activate CYCLIC SLEEP mode, don't reset ME
Query ME mode
Set ME back to normal (default parameters: 1,0)