At+Csmp Set Sms Text Mode Parameters - Siemens TC63 Command Set

Cellular engine
Table of Contents

Advertisement

TC63 AT Command Set
13.16 AT+CSMP
13.16

AT+CSMP Set SMS text mode parameters

Syntax
Test Command
AT+CSMP=?
Response(s)
OK
Read Command
AT+CSMP?
Response(s)
+CSMP:<fo>, <vp>/ <scts>, <pid>,
OK
Write Command
AT+CSMP=<fo>[, <vp>/<scts>[, <pid>[, <dcs>]]]
Response(s)
+CSMP:
<index>
OK
If sending fails
ERROR
+CMS ERROR
Reference(s)
GSM 07.05
Command Description
The write command selects values for additional parameters needed when SM is sent to the network or placed
in a storage when text format message mode is selected.
It is possible to set the validity period starting from when the SM is received by the SMSC
255) or define the absolute time of the validity period termination
by <fo>. If TA supports the enhanced validity period format, see GSM 03.40), it shall be given as a hexadecimal
coded string (e.g. <pdu>) with quotes.
Parameter Description
(num)
<fo>
First Octet
depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17),
SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format
(&F)
0...17
...255
(num)
<vp>
Depending on SMS-SUBMIT
string format (refer <dt>)
(&F)
0...167
...255
(num)
<dcs>
Data Coding Scheme
GSM 03.38 SMS Data Coding Scheme, or Cell Broadcast Data Coding Scheme in integer format
(&F)
0
...247
TC63_ATC_V00.490
Confidential / Draft - Do not copy
<dcs>
PIN
%
setting: GSM 03.40 TP-Validity-Period either in integer format or in time-
<fo>
Page 345 of 501
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
%
%
%
%
(<vp>
is a string). The format of
s
Last
%
%
!
%
!
(<vp>
is in range 0...
is given
<vp>
5/24/05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents