At^stpb Transmit Parity Bit (For 7E1 And 7O1 Only) - Siemens TC63 Command Set

Cellular engine
Table of Contents

Advertisement

TC63 AT Command Set
4.11 AT^STPB
4.11

AT^STPB Transmit Parity Bit (for 7E1 and 7O1 only)

This command is intended only for use with 7E1 and 7O1. In addition to the 7E1 or 7O1 settings made with
the command
AT+ICF
AT^STPB
Syntax
Test Command
AT^STPB=?
Response(s)
^STPB: (list of supported <n>s)
OK
Read Command
AT^STPB?
Response(s)
^STPB:
<n>
OK
Write Command
AT^STPB=<n>
Response(s)
OK
ERROR
+CME ERROR: unknown
Reference(s)
SIEMENS
Command Description
The test command returns the supported values of the parameter <n>.
The read command returns the current value of the parameter <n>.
The write command can be used to control the handling of the parity bit. If command fails, "+CME ERROR:
unknown" will be returned.
Parameter Description
(num)(&W)
<n>
(&F)
0
1
TC63_ATC_V00.490
Confidential / Draft - Do not copy
specifies whether or not to transmit the parity bit over the air.
PIN
!
The parity bit will not be transmitted over the air and will be replaced with 0.
This mode is the default setting if 7E1 or 7O1 is activated with AT+ICF.
In a data connection 8 bits will be transmitted, including the parity bit, i.e. the
parity bit will be properly transmitted over the air. The setting shall be used if
problems are encountered when TC63 is running in the default 7E1 or 7O1
mode enabled with AT+ICF. In this case, AT^STPB=1 shall be set in addition
to the 7E1 or 7O1 settings selected with AT+ICF.