Sign In
Upload
Manuals
Brands
Siemens Manuals
Accessories
MC35 Terminal
Siemens MC35 Terminal Manuals
Manuals and User Guides for Siemens MC35 Terminal. We have
3
Siemens MC35 Terminal manuals available for free PDF download: Command Set, User Manual, Migration Manual
Siemens MC35 Terminal Command Set (256 pages)
Module/Terminal
Brand:
Siemens
| Category:
Accessories
| Size: 1.88 MB
Table of Contents
Table of Contents
3
Version History
9
1 Introduction
13
Scope of the Document
13
Table 1: Product Specific Use of at Commands
13
Supported Product Versions and Related Documents
14
Conventions
15
AT Command Syntax
15
Using Parameters
15
Table 2: Types of at Commands and Responses
15
Combining at Commands on the same Command Line
16
Entering Successive at Commands on Separate Lines
16
Table 3: Illegal Combinations of at Commands
16
Supported Character Sets
17
Table 4: Character Definitions Depending on Alphabet (Examples)
17
Flow Control
18
Software Flow Control (XON/OFF Flow Control)
18
Hardware Flow Control (RTS/CTS Flow Control)
18
2 Standard V.25Ter at Commands
19
A/ Repeat Previous Command Line
19
Switch from Data Mode or PPP Online Mode to Command Mode
19
At\Qn Flow Control
20
ATA Answer a Call
20
ATD Mobile Originated Call to Dial a Number
21
Atd><Mem><N> Originate Call to Phone Number <N> in Memory <Mem
23
Atd><N> Originate Call to Phone Number Selected from Active Memory
25
Atd><Str> Originate Call to Phone Number in Memory with Corresponding Field
26
ATDI Mobile Originated Call to Dialable ISDN Number <N
27
ATDL Redial Last Telephone Number Used
28
ATE Enable Command Echo
29
ATH Disconnect Existing Connection
29
ATI Display Product Identification Information
30
Ati[Value] Display Additional Identification Information
30
ATL Set Monitor Speaker Loudness
31
ATM Set Monitor Speaker Mode
31
ATO Switch from Command Mode to Data Mode / PPP Online Mode
31
ATQ Set Result Code Presentation Mode
32
ATP Select Pulse Dialling
32
ATS0 Set Number of Rings before Automatically Answering the Call
32
ATS3 Write Command Line Termination Character
33
ATS4 Set Response Formatting Character
33
ATS5 Write Command Line Editing Character
33
ATS6 Set Pause before Blind Dialling
34
ATS7 Set Number of Seconds to Wait for Connection Completion
34
ATS8 Set Number of Seconds to Wait for Comma Dial Modifier
34
ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier
35
ATS18 Extended Error Report
35
ATT Select Tone Dialling
35
ATV Set Result Code Format Mode
36
ATX Set CONNECT Result Code Format and Call Monitoring
36
ATZ Set All Current Parameters to User Defined Profile
37
AT&C Set Circuit Data Carrier Detect (DCD) Function Mode
37
AT&D Set Circuit Data Terminal Ready (DTR) Function Mode
38
AT&F Set All Current Parameters to Manufacturer Defaults
39
Table 5: Factory Settings
39
AT&S Set Circuit Data Set Ready (DSR) Function Mode
41
AT&V Display Current Configuration
42
AT&W Store Current Configuration to User Defined Profile
43
AT+GCAP Request Complete TA Capabilities List
44
AT+GMI Request Manufacturer Identification
44
AT+GMM Request TA Model Identification
44
AT+GMR Request TA Revision Identification of Software Status
45
AT+GSN Request TA Serial Number Identification(IMEI)
45
AT+ILRR Set TE-TA Local Rate Reporting
46
AT+IPR Set Fixed Local Rate
47
Autobauding
48
3 AT Commands for FAX
49
AT+FBADLIN Bad Line Treshold
49
AT+FBADMUL Error Threshold Multiplier
50
AT+FBOR Query Data Bit Order
50
AT+FCIG Query or Set the Local Polling ID
51
AT+FCLASS Fax: Select, Read or Test Service Class
51
AT+FCQ Copy Quality Checking
52
AT+FCR Capability to Receive
52
AT+FDCC Query or Set Capabilities
53
AT+FDFFC Data Compression Format Conversion
54
AT+FDIS Query or Set Session Parameters
55
AT+FDR Begin or Continue Phase C Data Reception
56
AT+FDT Data Transmission
56
AT+FET End a Page or Document
57
AT+FK Kill Operation, Orderly FAX Abort
57
AT+FLID Query or Set the Local ID Setting Capabilities
57
AT+FMDL Identify Product Model
58
AT+FMFR Request Manufacturer Identification
58
AT+FOPT Set Bit Order Independently
58
AT+FPHCTO DTE Phase C Response Timeout
59
AT+FREV Identify Product Revision
59
AT+FRH Receive Data Using HDLC Framing
59
AT+FRM Receive Data
60
AT+FRS Receive Silence
60
AT+FTH Transmit Data Using HDLC Framing
60
AT+FTM Transmit Data
61
AT+FTS Stop Transmission and Wait
61
AT+FVRFC Vertical Resolution Format Conversion
62
4 AT Commands Originating from GSM 07.07
63
AT+CACM Accumulated Call Meter (ACM) Reset or Query
63
AT+CALA Set Alarm Time
64
Table 6: Summary of at Commands Available in Alarm Mode
66
AT+CAMM Accumulated Call Meter Maximum (Acmmax) Set or Query
67
AT+CAOC Advice of Charge Information
68
AT+CBST Select Bearer Service Type
69
AT+CCFC Call Forwarding Number and Conditions Control
70
Examples: Call Forwarding
71
AT+CCLK Real Time Clock
73
AT+CCUG: Closed User Group
74
AT+CCWA Call Waiting
75
AT+CEER Extended Error Report
77
AT+CFUN Set Phone Functionality
78
Wake up the ME from SLEEP Mode
81
Table 7: Wake-Up Events in NON-CYCLIC and CYCLIC SLEEP Mode
81
AT+CGMI Request Manufacturer Identification
82
AT+CGMM Request Model Identification
82
AT+CGMR Request Revision Identification of Software Status
82
AT+CGSN Request Product Serial Number Identification (IMEI) Identical to GSN
83
AT+CHLD Call Hold and Multiparty
83
AT+CHUP Hang up Call
84
AT+CIMI Request International Mobile Subscriber Identity
84
AT+CIND Indicator Control
85
AT+CLCC List Current Calls of ME
87
AT+CLCK Facility Lock
88
Examples: Enabling / Disabling PIN 1 Authentication
90
Examples: Phone Lock
91
Examples: Call Barring
93
AT+CLIP Calling Line Identification Presentation
94
AT+CLIR Calling Line Identification Restriction (by *# Sequence)
95
AT+CLVL Loudspeaker Volume Level
96
AT+CMEE Report Mobile Equipment Error
97
AT+CMER Mobile Equipment Event Reporting
98
AT+CMUT Mute Control
100
AT+CMUX Enter Multiplex Mode
101
Restricted Use of at Commands in Multiplex Mode
102
Table 8: Availability of at Commands on Virtual Channels
102
Table 9: Summary of at Commands with Different Behaviour in Multiplex Mode
103
AT+COPN Read Operator Names
104
AT+COPS Operator Selection
105
AT+CPAS Mobile Equipment Activity Status
107
AT+CPBR Read Current Phonebook Entries
108
AT+CPBS Select Phonebook Memory Storage
109
AT+CPBW Write Phonebook Entry
110
AT+CPIN Enter PIN
111
What to Do if PIN or Password Authentication Fails
114
Table 10: Timing Algorithm of Incorrect Password Input
114
AT+CPIN2 Enter PIN2
116
AT+CPUC Price Per Unit and Currency Table
118
AT+CPWD Change Password
119
AT+CR Service Reporting Control
122
AT+CRC Set Cellular Result Codes for Incoming Call Indication
123
AT+CREG Network Registration
124
AT+CRLP Select Radio Link Protocol Param. for Orig. Non-Transparent Data Call
126
AT+CRSM Restricted SIM Access
127
AT+CSCS Set te Character Set
128
AT+CSNS Single Numbering Scheme
129
AT+CSQ Signal Quality
130
AT+CSSN Supplementary Service Notifications
131
AT+CUSD Unstructured Supplementary Service Data
132
At+Vtd=<N> Tone Duration
133
AT+VTS DTMF and Tone Generation (<Tone> in {0-9, *, #, A, B, C, D})
133
AT+WS46 Select Wireless Network
134
5 AT Commands Originating from GSM 07.05 for SMS
135
AT+CMGC Send an SMS Command
135
AT+CMGD Delete SMS Message
136
AT+CMGF Select SMS Message Format
136
AT+CMGL List SMS Messages from Preferred Store
137
AT+CMGR Read SMS Message
140
AT+CMGS Send SMS Message
143
AT+CMGW Write SMS Message to Memory
145
AT+CMSS Send SMS Message from Storage
147
AT+CNMA New SMS Message Acknowledge to ME/TE, Only Phase 2
148
AT+CNMI New SMS Message Indications
149
AT+CPMS Preferred SMS Message Storage
152
AT+CSCA SMS Service Centre Address
154
AT+CSCB Select Cell Broadcast Messages
155
AT+CSDH Show SMS Text Mode Parameters
156
AT+CSMP Set SMS Text Mode Parameters
157
AT+CSMS Select Message Service
158
6 GPRS at Commands in Accordance with GSM 07.07
159
Commands Specific to Mts Supporting GPRS
159
AT+CGATT GPRS Attach and Detach
159
AT+CGACT PDP Context Activate or Deactivate
160
AT+CGDATA Enter Data State
161
AT+CGDCONT Define PDP Context
162
AT+CGQMIN Quality of Service Profile (Minimum Acceptable)
164
AT+CGQREQ Quality of Service Profile (Requested)
168
AT+CGSMS Select Service for MO SMS Messages
172
AT^SGAUTH Set Type of Authentication for PPP Connection
173
Modem Compatibility Commands to Mts Supporting GPRS
174
ATD *99# Request GPRS Service
174
ATD *98# Request GPRS IP Service
175
ATH Manual Rejection of a Network Request for PDP Context Activation
176
Using GPRS at Commands (Examples)
177
Miscellaneous at Commands
177
Using the GPRS Dial Command ATD
179
7 AT Commands for SIM Application Toolkit (GSM 11.14)
180
AT^SSTA Remote-SAT Interface Activation
181
SSTN Remote-SAT Notification
182
AT^SSTGI Remote-SAT Get Information
183
AT^SSTR Remote-SAT Response
184
8 Siemens Defined at Commands for Enhanced Functions
185
AT+CXXCID Display Card ID (Identical to AT^SCID)
185
AT^MONI Monitor Idle Mode and Dedicated Mode
186
AT^MONP Monitor Neighbour Cells
188
AT^SACM Advice of Charge and Query of ACM and Acmmax
189
AT^SBC Battery Charging / Discharging and Charge Control
190
Table 11: Summary of at Commands Available in Charge-Only and Alarm Mode
192
AT^SCID Display SIM Card Identification Number
193
AT^SCKS Set SIM Connection Presentation Mode and Query SIM Connection Status
194
AT^SCNI List Call Number Information
195
AT^SCTM Set Critical Operating Temperature Presentation Mode or Query Temperature
196
AT^SDLD Delete the "Last Number Redial" Memory
198
AT^SHOM Display Homezone
198
AT^SLCD Display Last Call Duration
198
AT^SLCK Facility Lock
199
AT^SMGL List SMS Messages from Preferred Storage
201
AT^SMGO Set or Query SMS Overflow Presentation Mode or Query SMS Overflow
202
AT^SMSO Switch off Mobile Station
203
AT^SMGR Read SMS Message Without Set to REC READ
203
AT^SM20 Set M20 Compatibility
204
AT^SNFA Set or Query Microphone Attenuation
205
AT^SNFD Set Audio Parameters to Manufacturer Default Values
206
AT^SNFI Set Microphone Path Parameters
207
AT^SNFM Mute Microphone
208
Audio Programming Model
208
Figure 1: at Audio Programming Model
208
AT^SNFO Set Audio Output (= Loudspeaker Path) Parameter
209
AT^SNFPT Call Progress Tones
210
AT^SNFS Select Audio Hardware Set
211
AT^SNFV Set Loudspeaker Volume
212
AT^SNFW Write Audio Setting in Non-Volatile Store
212
AT^SPBC Search the First Entry in the Sorted Telephone Book
213
AT^SPBG Read Entry from Active Telephone Book Via Sorted Index
214
AT^SPBS Steps the Selected Phonebook Alphabetically
215
AT^SPIC Display PIN Counter
216
AT^SPLM Read the PLMN List
217
AT^SPLR Read Entry from the Preferred Operators List
218
AT^SPLW Write an Entry to the Preferred Operators List
219
AT^SPWD Change Password for a Lock
220
AT^SRTC Select, Query, Test Ring Tone Parameters
222
AT^SSCONF SMS Configuration
224
AT^SSDA Set Display Availability
225
AT^SSYNC Configure SYNC Pin
226
Table 12: Operating Modes of the ME Indicated by Status LED (if <Mode> = 1)
227
AT^STCD Display Total Call Duration
228
9 Appendix
229
Summary of ERRORS and Messages
229
Summary of CME ERRORS Related to GSM 07.07
229
Summary of GPRS-Related CME ERRORS
230
Summary of CMS ERRORS Related to GSM 07.05
231
Summary of Unsolicited Result Codes (URC)
234
Table 13: Summary of Urcs
234
Table 14: Summary of Fax Class 2 Urcs Defined by EIA PN-2388
236
Result Codes
237
Cause Location ID for the Extended Error Report (AT+CEER)
237
GSM Release Cause for L3 Radio Resource (RR) (AT+CEER)
238
SIEMENS Release Cause for L3 Radio Resource (RR) (AT+CEER)
238
GSM Release Cause for Mobility Management (MM) (AT+CEER)
239
SIEMENS Release Cause for L3 Mobility Management (MM) (AT+CEER)
240
GSM Release Cause for L3 Call Control (CC) (AT+CEER)
240
SIEMENS Release Cause for L3 Call Control (CC) (AT+CEER)
241
SIEMENS Release Cause for L3 Advice of Charge (AOC) (AT+CEER)
242
GSM Release Cause for Supplementary Service Call (AT+CEER)
242
Siemens Release Cause for Call Related Supplementary Services (CRSS) (AT+CEER)
243
GSM Release Cause for Session Management (SM) (AT+CEER)
243
SIEMENS Release Cause for Session Management (SM) (AT+CEER)
244
SIEMENS Release Cause for GPRS API (AT+CEER)
244
SIEMENS Release Cause for Embedded Netcore (AT+CEER)
245
Summary of PIN Requiring at Commands
246
AT Commands Available before Entering the SIM PIN
248
Standard GSM Service Codes
250
Table 15: GSM Service Codes
250
Additional Notes on ^SCCFC, ^SCCWA, ^SCLCK
252
GSM and UCS2 Alphabet Tables
254
Advertisement
Siemens MC35 Terminal User Manual (64 pages)
Remote-SAT
Brand:
Siemens
| Category:
Modem
| Size: 0.63 MB
Table of Contents
Table of Contents
3
1 AT Commands for Remote-SAT in MC35
4
Introduction
4
Supported Product Versions and Related Documents
5
SAT Context Diagram
6
Usage of Remote-SAT
7
Command Type Values
7
Command Name
8
Parameter Types
9
States of Remote-SAT
9
Examples: Using Remote-SAT
12
Sequence Scenarios
14
AT^SSTA Remote-SAT Activation
19
SSTN Remote-SAT Notification
21
AT^SSTGI Remote-SAT Get Information
22
AT^SSTGI Remote-SAT Get Information - Generic Format
22
AT^SSTGI Remote-SAT Get Information - Refresh (1)
23
AT^SSTGI Remote-SAT Get Information - Set up Event List (5)
24
AT^SSTGI Remote-SAT Get Information - Setup Call (16)
25
AT^SSTGI Remote-SAT Get Information - Send SS (17)
27
AT^SSTGI Remote-SAT Get Information - Send USSD (18)
28
AT^SSTGI Remote-SAT Get Information - Send Short Message (19)
29
AT^SSTGI Remote-SAT Get Information - Send DTMF (20)
30
AT^SSTGI Remote-SAT Get Information - Play Tone (32)
31
AT^SSTGI Remote-SAT Get Information - Display Text (33)
32
AT^SSTGI Remote-SAT Get Information - Get Inkey (34)
33
AT^SSTGI Remote-SAT Get Information - Get Input (35)
34
AT^SSTGI Remote-SAT Get Information - Select Item (36)
35
AT^SSTGI Remote-SAT Get Information - Setup Menu (37)
37
AT^SSTGI Remote-SAT Get Information - Setup Idle Mode Text (40)
38
AT^SSTR Remote-SAT Response - Generic Format
39
Remote-SAT Command Status
41
Proactive Commands
42
Event Response Commands
55
2 Appendix
57
Appendix A - SAT Profile
57
Appendix B - UCS2 Character Set Options
60
Appendix C - Language Codes
61
Siemens MC35 Terminal Migration Manual (30 pages)
Cellular Engine
Brand:
Siemens
| Category:
Control Unit
| Size: 0.63 MB
Table of Contents
Table of Contents
3
1 Revision History
5
2 General Information
6
How to Use this Document
6
Related Documents
6
3 Feature Migration
7
General Description
7
Table 1: General Description A)
7
Certification and Standards
8
Table 2: General Description B)
8
4 Hardware Migration
9
Introduction
9
Operating Modes
10
Table 3: Operating Modes
10
Table 4: Wake up from SLEEP Mode
11
MC35 / Mc35I - Interface and Connector Comparison
12
Table 5: Host Interface PIN Assignment - ZIF Connector
12
Power Supply
13
Table 6: Power Supply Signals
13
Table 7: Current Consumption Comparison
13
Table 8: Maximum Ratings and the Associated Urcs
14
RTC Backup
15
Control Signals
15
Interfaces
15
Table 9: Serial Interface
15
Electrostatic Discharge
16
Mechanical Dimensions
16
Mounting and Installation
18
5 At Commands Migration
19
General Comments
19
List of Jointly Supported at Commands
20
Table 10: Standard V.25Ter at Commands
20
Table 11: at Commands for FAX
22
Table 12: at Commands from GSM 07.07
23
Table 13: at Commands for SMS
25
Table 14: GPRS at Commands
25
Table 15: SIM Application Toolkit at Commands
25
Table 16: Siemens Defined at Commands
26
List of New AT-Commands
28
List of Unsupported AT-Commands
28
List of AT-Commands for V.25Ter Compatibility
28
Table 17: New GPRS at Commands
28
Table 18: New Siemens Defined at Commands
28
Table 19: V.25Ter Compatibility Commands
28
6 Terms and Abbreviations
29
Table 20: Glossary of Terms
29
Advertisement
Advertisement
Related Products
Siemens Brodersen MC55
Siemens Milltronics MD-36
Siemens Milltronics Millpulse 600
Siemens SIMATIC MOBY D MDS D324
Siemens SIMATIC MOBY D MDS D460
Siemens SIMATIC MOBY D MDS D165
Siemens SIMATIC MOBY D MDS D261
Siemens SIMATIC MOBY D MDS D139
Siemens milltronics WEIGHFEEDER 1200 Series
Siemens Milltronics TASS
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL