Current Analog Output (Ma); Pulses Per Belt Revolution; Pulses Per Second At Nominal Speed; Pulses Per Second - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

8.23.4

Current analog output (mA)

The actual value of the current (in mA) which is output at the analog output.
8.23.5

Pulses per belt revolution

Number of sensor pulses per belt revolution.
8.23.6

Pulses per second at nominal speed

This parameter is determined during the belt calculation and indicates how many impulses
are output per second by the pulse sensor at the design speed.
8.23.7

Pulses per second

Current integer value of impulses per second.
8.23.8

Nominal boat load

The nominal belt load is entered during initial commissioning. It is the basis for generating
limits (DR 6), and is calculated from design flow rate / design speed.
8.23.9

Refresh counter for process values

Measured values are calculated every 10 ms in the SIWAREX module. A counter is
incremented by 1 each time. Once the counter reaches the value 65536, it starts again from
zero. The counter can be used as a time stamp for data record DR 31.
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Scale parameters and functions of the belt scale
8.23 DR 31 Process state extended
129